SeQual Eclipse 3 with autoSAT Technology Portable Oxygen Unit
The 3rd Generation Eclipse has Arrived!
The Eclipse 3, Personal Ambulatory Oxygen System (PAOS) provides the
most reliable continuous flow and pulse dose options in a 24/7 portable device.
It is one device for both stationary and ambulatory oxygen needs.
- Small, lightweight & easy-to-use
- autoSAT Technology & revolutionary clinical features
- Runs on battery, AC & DC power
- Universal large-wheeled cart with easy battery access
The Eclipse 3 lowers operational costs by reducing monthly deliveries
and simplifying inventory management and space the clear choice
for a non-delivery model.
Simple.
The Eclipse 3 is a single solution, better for your patients and your business.
• Offers both continuous flow and pulse dosing options
• One machine for stationary, ambulatory and travel needs
• Lower operational costs by reducing monthly deliveries and simplifying
inventory management
• Maximum Medicare reimbursement with two billing codes: E1390 & E1392
• Longer service intervals with lower maintenance costs
• The only system on the market that can be upgraded in the field as new technology
becomes available
Trusted.
Patients want the freedom to enjoy life at a moment’s notice and the peace of
mind that the reliable Eclipse 3 delivers. It keeps up with the various activities of daily living
while providing the individualized oxygen prescription.
• Active and healthier patients create stronger referrals
• Simplifies the patients’ continuum of care with one device
• No waiting for cylinder deliveries and replaces bulky equipment
• The sleek design is small, quiet and can lower electric bills
• AC/DC and battery power options extend therapy time and patient travel
• FAA Approved for commercial airline travel
• Accessory options that support an active lifestyle
Proven.
The AARC suggests “titrate to saturate” and the Eclipse was developed with that
theory in mind. With a comprehensive dosing selection, a broader patient population can be
treated at rest, during sleep, at exercise and at altitude. It’s superior oxygen delivery.
• autoSAT Technology, a pulse delivery system, maintains a consistent pulse dose volume for
every breath as your patient’s respiratory rate changes
• Consistently delivers a fixed pulse dose volume up to 96mL (in increments of 16mL)
in addition, three new pulse dose volumes of 128mL, 160mL and 192mL
• New control panel displays in either LPM or mL for a more accurate prescription verification
• Can be used with CPAP and bi-level devices in Continuous Flow
Eclipse 3 Oxygen System Specifications*
Size: H x W x D 19.3 x 12.3 x 7.1 inches
Weight: Eclipse 15 pounds; Power Cartridge 3.4 pounds
Continuous Flow settings 0.5 to 3.0 LPM (0.5 liter increments)
(measured in Liters Per Minute LPM)
Pulse Dose settings 16-96 (16mL increments), 128mL, 160mL, 192mL
(measured in mL)
Oxygen concentration 90% ± 3% @ sea level
Oxygen output pressure 5.0 psig (34.5 kPa) nominal
Sound level 48 dB(A) at 3.0 LPM Continuous Flow Mode
40 dB(A) at 3.0 Pulse Dose setting
Power specifications:
AC Operation 100-240 VAC, 50-60 Hz
DC Operation 12 V nominal
Power Cartridge Quantity (2) 97.5 W-Hr battery packs each containing
7.92 grams of equivalent lithium content
Power Consumption 52 watts at 1.0 LPM continuous flow
145 watts at 3.0 LPM continuous flow
45 watts at 1.0 pulse dose setting
95 watts at 6.0 pulse dose setting
Nominal Power Cartridge 2.0 hours at 2.0 LPM continuous flow
operating time 1.3 hours at 3.0 LPM continuous flow
5.2 hours at 2.0 pulse dose setting,12bpm
3.5 hours at 6.0 pulse dose setting,12bpm
Power Cartridge 1.8 to 5.0 hrs, dependent upon the flow recharge time setting,
recharge time to achieve 80% capacity from a fully discharged Power Cartridge
Back up alarm power 9 Volt battery
Operating temperature 50° F to 104° F (10° C to 40° C) at
82.4° F (28° C) dew point, non-condensing
|